Programming PLC Functions
4.6 Cross-channel status display
HEADER.INI file:
[Pos1]
ChanStatFeedStopSpindleStop = 3
Spindles = 1,2
[Pos3]
ChanStatFeedStop = 2
[Pos5]
SpindStat= 3
The following display, for example, appears in the program status line:
Figure 4-3
Deactivating
Icon displays configured in this way can be deactivated if user status displays are used as
described in B. Create empty entries in a user-specific HEADER.INI file (not in the hmi_adv
directory, because this would be overwritten again when the software is upgraded).
Example:
[Pos5]
SpindStat=<EMPTY>
See also
HEADER.INI (Page 283)
128
;
;
;
;
;
;
Program status line with icons (2)
first display position
Channel status of channel 3 is displayed,
superimposed with feed inhibit channel 3
and spindle inhibit for spindles1 and 2
third display position
Channel status of channel 2 is displayed
superimposed with the feed inhibit,
channel 2
fifth display position
spindle status for spindle 3 is displayed