Siemens SINUMERIK Commissioning Manual page 115

Sinumerik 840di sl/840d sl/840dbase software and hmi advanced
Hide thumbs Also See for SINUMERIK:
Table of Contents

Advertisement

Determining the normalization factor
The normalization factor is determined by measuring the spindle using a function generator,
servo trace function, and information in the motor data sheet.
Function generator
Figure 3-4
1. Open the following window in the "Start-up" → "Optimization/Test" → "Function Generator"
2. In the screen form that appears, select a signal, a signal type and a factor for
3. Continue by pressing the "Signal parameters" softkey. The "Function generator
4. Enter the settings for amplitude, cycle duration, pulse width, and limitation. Refer to the
HMI Advanced (IM4)
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
Function generator
operating area:
normalization under "Mode".
parameters" screen form is displayed.
motor data sheet to obtain this data.
NOTICE
If the function generator and measuring function are used on virtual axes, this leads to
an abort by the NCK.
Parameterizing machine data
3.2 Parameterizing the control using machine data
109