Configuring the HMI system
2.1 Processing INI files
Settings in the REGIE.INI file:
Default: No prompt dialog box
[Miscellaneous]
EnableRebootDialog = True
If the protection level is lower than the manufacturer level (protection level 0 to 2) or if the
above entry is set to "False" in the REGIE.INI file, the prompt can be confirmed with:
OK
Cancel
If you have the applicable access authorizations (protection level 3 to 7), the following option
is offered:
Restart
Exit
Cancel
2.1.4
Setting the storage location for the alarm log
Function
Two different methods are available saving the alarm profile on the hard disk. The
application and the disk load must be taken into account when selecting which method to
use. The required entries are made in the MBDDE.INI file.
Writing to alarm files always places a load on the same hard disk region. Various methods
can be chosen with the following control options.
There are a number of strategies for reducing the load on the disk. Multiple log files can be
maintained in parallel on the disk. With the multiple file strategy, the next file is selected each
time the HMI is booted. This reduces the load on the disk hardware, both in the data area as
well as the directory information area. In addition, this strategy detects physical disk errors in
the data area on startup and avoids them by reallocating memory space.
The multiple file strategy can also be selected using the following entry in the file mbdde.ini.
[PROTOCOL]
DiskCare
The following values are possible:
DiskCare=-1
DiskCare=0
24
HMI is closed and Windows XP is shutdown.
HMI is not closed
HMI and Windows XP are closed and then restarted.
HMI is closed and Windows XP is shutdown.
HMI is not closed
The MBDDE server controls the alarm log in the memory. The alarm
log is saved on the hard disk if it is displaced in the operator area
"Diagnostics" of if the key <Alarm Cancel> is pressed.
The data is written to the log file immediately.
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0