Column properties cannot be read in the LOAD block.
The wr, ac and li attributes can be specified for column definitions.
See also
Dialog elements (Page 2-13)
List of accessible system variables (Page A-7)
2.4.8
Focus control in the table grid
Description
The Row and Col properties can be used to set and calculate the focus within a table:
● Identifier.Row
● Identifier.Col
Programming
Each cell in a table has the Val and Vld properties.
In order to read and write cell properties, a line and column index must be specified in
addition to the variable identifiers from the definition list.
Syntax:
Description:
Syntax:
Description:
Example
Var1[2,3].val=1.203
If the line and column indices are not specified, the indices of the focused cell apply. This
corresponds to:
Var1.Row =2
Var1.Col=3
Var1.val=1.203
Expanding the user interface
Commissioning Manual, 11/2006, 6FC5397-0DP10-0BA0
Identifier[Line index, column index].val or
Identifier[Line index, column index]
Val properties
Identifier[Line index, column index].vld