Siemens SINUMERIK Commissioning Manual page 107

Sinumerik 840di sl/840d sl/840dbase software and hmi advanced
Hide thumbs Also See for SINUMERIK:
Table of Contents

Advertisement

REDEF $MA_ENC_SEGMENT_NR APR 2 APW 2
REDEF $SN_JOG_CONT_MODE_LEVELTRIGGRD APR 2 APW 2
M30
MD 30100: $MA_CTRLOUT_SEGMENT_NR has access level 2/7, i.e. access level 2 is
required for write access (corresponding to password) and access level 7 for read access.
In order to access the machine data area, key-operated switch setting 3 or higher is
required.
Undoing the access level change
In order to undo access level changes, the original values have to be restored.
Example:
_N_DEF_DIR/__N_SGUD_DEF
REDEF $MA_CTRLOUT_SEGMENT_NR APR 7 APW 2
REDEF $MA_ENC_SEGMENT_NR APR 0 APW 0
REDEF $SN_JOG_CONT_MODE_LEVELTRIGGRD APR 7 APW 7
M30
Definition files for REDEF
For programming REDEF commands - the same as for the GUD definitions - separate
definition files exist, which are evaluated when then control boots.
/_N_DEF_DIR/_N_UACCESS_DEF
/_N_DEF_DIR/_N_MACCESS_DEF
/_N_DEF_DIR/_N_SACCESS_DEF
A additional Siemens definition file, which is used to configure the system, is saved on the
PCMCIA card or CF card in the NC system software.
HMI Advanced (IM4)
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
Parameterizing machine data
3.2 Parameterizing the control using machine data
MD 30210
; (APW ... Write access)
SD 41050
; File for global variables
; $PATH=/_N_DEF_DIR
; (APR ... Read access)
; (APW ... Write access)
// Definition file for access level instructions of the
end user
// Definition file for access level instructions of the
manufacturer
// Definition file for access level instructions for
Siemens system applications (e.g. standard
cycles, ShopMill, etc.)
101

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents