Siemens SINUMERIK Commissioning Manual page 299

Sinumerik 840di sl/840d sl/840dbase software and hmi advanced
Hide thumbs Also See for SINUMERIK:
Table of Contents

Advertisement

; example for usb device of tcu TCU1, port X203. for second port use
X204
; a partition number may be specified. if omitted,
; the default partition is 1
: the partition number has no effect on a usb device of the pcu
; Connection<index>=TCU:\\TCU1:X203,1
; any directory path can be append (TCU:\\TCU1:X204,2\Directory1),
; but it must exist on the device
[Connections]
; Connection1 to Connection<N> are read with the corresponding
access
; levels, empty entries are ignored
; N=0 to 8, if missing ConnectionNum is set to 8
; set ConnectionNum to 0 to ignore all entries of LOGDRIVE.INI
; and display machine data
; ConnectionNum=8
; usb device of current pcu/tcu, front
Connection1=ACTTCU:\\FRONT,1
AccessProgram1=7
AccessMachine1=7
AccessServices1=7
Example: Entries in the logdrive.ini
[Connections]
Connection1=ACTTCU:\\FRONT
SK_Connection1=FRONT_USB
AccessMachine1=7
AccessProgram1=7
AccessServices1=7
.
.
.
Connection5=TCU:\\station2:X203
SK_Connection5=Labeling5
AccessMachine5=6
AccessProgram5=6
AccessServices5=6
Connection6=TCU:\\station3:X204
HMI Advanced (IM4)
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
List of the INI Files
A.14 LOGDRIVE.INI
293

Hide quick links:

Advertisement

Table of Contents
loading