[NCK3.1]
logNCName = NCU_3
ChanNum = 1
Note
Function 1:N for solution line
• An HMI-Advanced can be switched over to as many as 4 NCUs.
• Drive alarms from an NCU which is not currently linked with the HMI are displayed as a
• The PLC block FB9 must not be used when switching over an MCP with the HMI (FB9
Solution
In the OB100 (the call for FB1), set MCP1BusAdr to 255 and MCP1Stop to true.
In the OB1, scan the "MMCBTSSready" (DB10.DBX108.3) signal. If this is set, write the
MCP address from DB19.DBB123 (MCP index) to the DB7.DBB27 before removing the MCP
stop bit DB7.DBX62.1. MCP is now active.
If the "MMCBTSSready" (DB10.DBX108.3) signal is now removed again (the HMI switches
to another NCU), the MCP stop bit DB7.DBX62.1 will have to be reset.
See also:
Function Manual Expansion Functions: Several Operator Panels on Several NCUs,
Distributed Systems (B3)
HMI Advanced (IM4)
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
group alarm. After the HMI has been switched over to the relevant NCU, the drive alarms
are shown in resolved form with all the details displayed.
must not be active). If necessary, the MCP must be switched over in the PLC user
program.