Siemens SINUMERIK Commissioning Manual page 40

Sinumerik 840di sl/840d sl/840dbase software and hmi advanced
Hide thumbs Also See for SINUMERIK:
Table of Contents

Advertisement

Configuring the HMI system
2.1 Processing INI files
Shortened configuration in TaskConf.INI
The above configuration of TASKCONF.INI for a softkey in the skeleton application can be
simplified for the following entries when standard operations are addressed:
HSK<SoftkeyIndex>Task= x/y
x operator area
y command or state= i
Example:
HSK1Task=Program/<root>
has the same priority as the full configuration:
HSK1Task=2
HSK1IsTask=0
HSK1Command=<root>
HSK1SkText=Program
Table 2- 1
Assignment of the tasks and softkey texts
x
y
Machine
<root>
Parameters
<root>
Program
<root>
Service
<root>
Diagnostics
<root>
Diagnostics
State=10
Diagnostics
State=20
Diagnostics
State=30
Diagnostics
State=40
Diagnostics
State=50
Setup
<root>
Setup
State=10
Setup
State=40
34
Explanation
Entry to the Machine main screen (task 0) with recall to the highest level for return. The
Machine
softkey text is
.
Entry into the Parameter main screen (task 1) with recall to the highest level for return.
Parameter
The softkey text is
Entry into the Program main screen (task 2) with recall to the highest level for return. The
Program
softkey text is
.
Entry into the Service main screen (task 3) with recall to the highest level for return. The
Services
softkey text is
.
Entry into the Diagnostics main screen (task 4) with recall to the highest level for return.
Diagnostics
The softkey text is
Entry into the Diagnostics main screen with recall to the highest level for return and
selection of the alarm screen.
Alarms
The softkey text is
Note:The entire horizontal diagnostics softkey bar can be used.
Entry into the Diagnostics main screen with recall to the highest level for return and
selection of the message screen.
Messages
The softkey text is
Entry into the Diagnostics main screen with recall to the highest level for return and
selection of the alarm log screen. The softkey text is
Entry into the Diagnostics service screen with recall to the highest level for return. The
Service displays
softkey text is
Entry into the Diagnostics PLC status screen with recall to the highest level for return. The
PLC status
softkey text is
Entry into the Start-up (task 5) main screen with recall to the highest level for return.
Start-up
The softkey text is
Entry into the Machine data screen with recall on exiting the level. The softkey text is
Machine data
.
Entry into the PLC overview screen in Start-up with recall on exiting the level. The softkey
PLC
text is
.
.
.
.
.
.
.
.
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
Alarm log
.
HMI Advanced (IM4)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents