Configuring the HMI system
2.1 Processing INI files
2.1.16
Activating the V.24 interface
Activating the V.24 interface
The serial V.24 interface can be activated in the DINO.INI file, section [System]. Here it is
possible to save files and assign them to the V.24/PG (COM1/COM2) interfaces.
The default setting is 0 (no interface parameterization).
[System]
; enable V24 setting by setting a non zero value
V24Settings=0
Procedure
To be able to use the V.24 data transfer with HMI-Advanced 7.5 on PCU 50.3, the following
steps are required:
1. In the BIOS of the PCU 50.3 under "Advanced → I/O Devices Configuration", set the
2. Insert the "PCI Interface Card (COM/LPT)" into the PCU 50.3 and install the supplied
3. In the Windows device manager, rename the COM interfaces as COM1, COM2.
4. In the Windows device manager, for each COM interface, under "Port Settings →
5. Activate the V.24 interface in the DINO.INI configuration file.
See also
DINO.INI (Page 277)
50
"Internal COM1" to "Disabled".
driver.
Advanced", deactivate the "Enable CTS/RTS Auto Flow Control" option.
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
HMI Advanced (IM4)