Configuring the HMI system
2.1 Processing INI files
Formats and data type
All entries are located in the [ACCESSMASKS] section. The entries have, e.g. the following
format:
[ACCESSMASKS]
\wks.dir\*.wpd\*.mpf =
\mpf.dir\*.mpf =
\cus.dir\*.spf =
A standard access mask can be declared for each data type and storage location. An entry
comprises the path at which data of the data type can be created and the new standard
access mask.
The paths are composed of the data type identifiers. In the example above,
"\wks.dir\*.wpd\*.mpf" comprises the data type for workpiece directories "wks.dir" the
workpieces "*.wpd" the part programs "*.mpf".
The new standard access mask 75775, with which new part programs are created, is defined
in all workpieces.
Access mask 75775 stands for:
7
5
7
7
5
See also
DH.INI (Page 280)
2.1.7
Configuring the '"Language Selection" softkey
Function
In order to select more than 2 languages on the control, the "Language Selection" softkey
can be configured in the main screen "Start-up" in order to change the language using the
menu.
The entry "SkSelectLngInsteadSkChangeLng" in the IB.INI file in the "[LANGUAGE]" section
controls whether the "Change Language" softkey in the main Start-up screen should be
replaced by the "Language Selection" softkey. If there is no
"SkSelectLngInsteadSkChangeLng" entry, then only "Change language" is available.
28
75775
75775
33773
Read access for all
Write authorization for protection level 5 and higher
Execution authorization is set
Display authorization for all
Delete authorization for protection level 5 and higher
0 to 7 are permissible
0 or 7 are permissible
0 or 7 are permissible
0 or 7 are permissible
0 to 7 are permissible