Diagnostics and service
5.6 Action log
Machine data for the action log
The machine data should be set to the following values:
General MD:
11295
PROTOC_FILE_MEM[9]
18370
MM_PROTOC_NUM_FILES[9]
18371
MM_PROTOC_NUM_ETPD_STD_LIST[9]
Channel MD
28300
MM_PROTOC_USER_ACTIVE[9]
28302
MM_PROTOC_NUM_ETP_STD_TYP[9]
Configuration file ACTLOG.INI
All settings of the action log are stored in file user\actlog.ini. Display MD 9012
ACTION_LOG_MODE has no meaning.
154
PLC signal:
(initiates writing to file CRASH.COM)
• Operating mode
• Actual main program that is selected (only AUTO)
• Actual block that is active (only AUTO and MDI) and
its predecessor and successor (three block display).
• Complete program level information (all assigned
program levels with the program names including
directory)
• Actual NC block pointer (only AUTO and MDI) all
levels
• All alarms and messages that are present
• Actual position of all of the axes in the WCS
• Actual position of all axes in the MCS
• Distance to go of all axes
• Program velocity (only AUTO and MDA)
• Programmed spindle speed (only AUTO and MDA)
• Actual spindle speeds
• Override influence of the axes and spindles
• Actual tool and active tool offset
• All active G functions
• All active frames, TRAFOS... if not clearly visible from
the G function.
• All active M functions
Value
Significance
Memory type of the log files:
0
= SRAM
1
= DRAM for solution line
3
Maximum number of log files
3
Number of standard ETPD data lists
Value
Significance
1
Activating logging for a user
3
Number of ETP standard event types
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0