Tool management
6.4 Job processing of tools
Parameter for PI TSEARCH
Note
Siemens reserves the right to withdraw support in future versions.
The parameters for the PI TSEARCH used for filtering can be specified for each filter.
This setting is very sensitive to errors. It does not support insertion of blanks; the number of
places must be strictly adhered to; the character string must be enclosed by " ".
There is one setting for each filter: n_FindPiSearchPar
● 8 parameters for PI SEARCH
● #Mag# can be used as a placeholder for the magazine setting. Constant, five-digit
● If the value in the 8th parameter is set to "2", filter criteria for cutting edge specific data
Example:
Paramtm.ini, [BatchTools]:
1_FindPiSearchPar="#Mag#,-0001,#Mag#,-0001,00000,00001,1,2"
252
magazine numbers can also be specified for the from/to magazine range instead of the
placeholder.
will also be used correctly for multi-point cutting tools (from NCK version NCK.P6_43 and
NCK.P5_20.4).
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
HMI Advanced (IM4)