Siemens SINUMERIK Commissioning Manual page 204

Sinumerik 840di sl/840d sl/840dbase software and hmi advanced
Hide thumbs Also See for SINUMERIK:
Table of Contents

Advertisement

Tool management
6.2 Settings in the configuration file
; in the magazine list and in the tool list.
; Example: ToolState_Lang_12345678=12345678_ToolState_Lang
MagPlaceState_Lang_12345678=12345678_MagPlaceState_Lang
; use patm_*.ini
; The new magazine location status bits can be displayed in each
; list display. The parameters are set in the sections:
"[1_MagList]", "[2_MagList]", "[3_MagList]"
"[1_ToolList]", "[2_ToolList]", "[3_ToolList]"
"[1_ActList]", "[2_ActList]", "[3_ActList]"
; Entries are for example:
12=TC_MPP4_9, 1, TC_MPP4_9 ;PlaceStatus Left,
;Reserved in left half location
13=TC_MPP4_10, 1, TC_MPP4_10 ;PlaceStatus Right,
;Reserved in right half location
14=TC_MPP4_11, 1, TC_MPP4_11 ;PlaceStatus Top,
;Reserved in upper half location
15=TC_MPP4_12, 1, TC_MPP4_12 ;PlaceStatus Bottom,
;Reserved in lower half location
16=TC_MPP4_13, 1, TC_MPP4_13 ;PlaceStatus Bit 13 of 1 to 16
17=TC_MPP4_14, 1, TC_MPP4_14 ;PlaceStatus Bit 14 of 1 to 16
18=TC_MPP4_15, 1, TC_MPP4_15 ;PlaceStatus Bit 15 of 1 to 16
19=TC_MPP4_16, 1, TC_MPP4_16 ;PlaceStatus Bit 16 of 1 to 16
; Example: MagPlaceState_Lang_12345678=12345678_MagPlaceState_Lang
; MagPlaceState_Lang_12345678=<Empty>
; For alphanumeric columns in a list:
; Width of a character in "twips". The approximate column width
; is calculated by multiplying the value entered here
; by the number of characters from the column parameter setting
ColumnWidthTwipsPerAlphaCharacter=140
; For numerical columns in a list:
; Width of a character in "twips". The approximate column width is
; calculated by multiplying the value entered here by
; the number of characters from the column parameter setting
ColumnWidthTwipsPerNumericCharacter=100
; Number of data elements in the magazine list or in the
; tool list at each internal data scan.
; Range: 1 to 27, default 18.
; As of version P4.3.8.the data-scanning rate has been
; improved.
; While internal data scanning is taking place, there is no
; response to softkey actuation. This time should therefore
; not exceed 1 second.
; The value from "NumLinesPerReq" is used to scan data from a
; complete list in the background, after a list has been
; selected by pressing a softkey or after startup.
; The number of visible lines in the list is used to retrieve data
; if the data display is refreshed after changes to
198
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
HMI Advanced (IM4)