Siemens SINUMERIK Commissioning Manual page 51

Sinumerik 840di sl/840d sl/840dbase software and hmi advanced
Hide thumbs Also See for SINUMERIK:
Table of Contents

Advertisement

Error messages
Error messages are displayed in the following cases:
If a part program that does not contain a valid INIT instruction is selected:
No INIT instruction found in the part program!
There is a reference to a non-existent file in the JOB/DAT file:
The following non-existent programs are addressed:
There is a reference to a non-existent channel number in the JOB/DAT file:
Programs that do not exist
are assigned to the following channels:
If no entry could be created in the DAT file:
No channel assignment found!
Additional configuring possibilities for multi-channel step sequence programming:
See also
MMC.INI (Page 303)
SEDITOR.INI (Page 317)
2.1.13
Tool management (WZV)
Function
The tool management HMI-Advanced already contains this functionality.
The structure of the NCDDE variables of tool management follows the pattern:
"TMHMICurData_"<MMCName>"_"<DataName>
with TMHMI = Tool Management Human Machine Interface
The following current data (<DataName>) are present:
General TOA and channel data:
- curTOANo current TOA number
- curChannelNo current channel number
Current tool in list views (tool in which the cursor lies) and in tool data images for individual
tools:
- curToolTNo T number
- curToolIdent tool identification
- curToolDuplo tool duplo number
- curToolType tool type
- curEdgeNo tool edge number, relative to the tool,
not the the Duplo number !
- curDLNo tool edge correction location number,
relative to the edge
HMI Advanced (IM4)
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
Configuring the HMI system
2.1 Processing INI files
45