Siemens SINUMERIK Commissioning Manual page 170

Sinumerik 840di sl/840d sl/840dbase software and hmi advanced
Hide thumbs Also See for SINUMERIK:
Table of Contents

Advertisement

Diagnostics and service
5.7 HMI Analyzer
PagePoolUsage
DiffPagePoolUsage
PageFaults
DiffPageFaults
Additional settings (below):
Cyclic
Reset
Single
Modules
System
Network
Note
Operating areas that are entered with PreLoad:=False in REGIE.INI and cannot be found as
a process are started by the HMI Analyzer before the analysis. The start is done via the
master control server (Regie server). During this, all the operating areas to be started are
activated by "SwitchToTask". After all the operating areas are started, the operating area
changes to "Machine".
When setting up a hotlink via the DCTL, a data query request is also sent via the DCTL. The
HMI Analyzer cannot display the current value for this request ("Value" column) .
164
Swap memory in KB
Modification of the swap memory since the start of the HMI Analyzer or
since the last reset
Access violations of the swap file
Modification of the access violations of the swap file since the start of
the HMI Analyzer or since the last reset
The view is cyclically updated. The differences since the start or since
the last reset are computed and displayed. The update rate can be
specified in milliseconds [ms] to the left next to the "Cyclic" selection.
Resets the differential values. This action can only be carried out for
cyclic display.
The view is updated once as a static display. The memory requirement
of all processes is re-evaluated.
When the Modules item is selected, the loaded DLLs for all running
processes are determined. When HMI-Advanced is running, the
applications of all operating areas that are entered with ProLoad;=False in
the Regie.ini are also started.
For this, the loaded DLLs are also determined.
Gives information on general PCU or PC data
Display of the current network data:
All the data that can be determined via the command "ipconfig /all" is
displayed. Für das Betriebssystem Windows NT wird zusätzlich noch
ermittelt, ob NetBeui installiert ist.
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0