Tool management
6.2 Settings in the configuration file
; If "MultiLine=SINGLE" appears in a list definition section of a
; magazine or tool list, then the cutting edge number
; can be specified by adding "@Ee", where "e" is the
; cutting edge number (range from 1 to the maximum number of
; cutting edges per tool) for all cutting edge data.
; This applies to the following data:
; Cutting edge data TC_DPp@Ee
; Cutting edge monitoring data TC_MOPp@Ee
; OEM cutting edge data TC_DPCp@Ee
; Freely assignable D No. TC_DPCE@Ee
; Additive offset TC_SCPz@Ee
; Setup compensation TC_ECPz@Ee
; If "@Ee" is not specified in these columns, then the data for
; cutting edge 1 is used. This method of proceeding is
; compatible with the earlier versions of P5. To avoid confusion,
; for these cutting edges you should specify the cutting edge
; number in the header text for the corresponding column.
; "@Ee" cannot be specified in magazine and tool lists
; for which "Multitime=MULTI" or with working offset lists.
; These values automatically display the data for the current
; cutting edges.
; "11": Approximate column width in characters, based on
; "[GeneralSettingsForMagAndToolList]", entries
; "ColumnWidthTwipsPer-AlphaCharacter" and
; "ColumnWidthTwipsPerNumericCharacter"
; second "TC_TP2": Column header text or code for
; text. If in the "[General]" section the entry for
; "ReadLanguageIni"="1", then the system searches for the column
header text
; in the files mmc2\language\patm_gr.ini,
; user\language\patm_gr.ini etc. in the section
; "[ListColumnHeaderText]", entry "TC_TP2" (in this example).
; The character string "gr" in "patm_gr.ini" depends on the
; particular language (see mmc.ini, "[LANGUAGE]", entry
; "Language=...").
; If the entry in Language\patm_gr.ini is found,
; then it is used as the column header text.
; If no entry is found or if the text "...=<Empty>"
; then the value from the paramtm.ini file
; is used as the column header text.
; If transformed data is displayed, then the column
; header text or its access code is also "transformed",
; in which the corresponding assignment of the section
; [ListColumnHeaderTrafoTextReplace] is used for substitution.
; (Therefore both the transformed/untransformed mechanism
; and the locale mechanism are used.)
; "WzIdent": ";" introduces a comment; at the end of a
; parameter line you can also introduce a comment with "//".
212
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0