Siemens SINUMERIK Commissioning Manual page 15

Sinumerik 840di sl/840d sl/840dbase software and hmi advanced
Hide thumbs Also See for SINUMERIK:
Table of Contents

Advertisement

Pressing the "Default address" softkey transfers the factory set IP address 192.168.214.1 to
the address field for the NCU.
However, if the control is linked to a company network, for example, the IP addresses will be
different. You must restart the HMI for the changes to take effect. The section with the new
IP address is written to user/mmc.ini.
Error when booting
The following error can occur while booting:
Alarm 120202: Waiting for a connection to the NC/PLC
Explanation:
Remedy:
Responses:
System settings
See the next chapter, System settings.
Printer selection
The softkey only works if at least one printer is installed under Windows. It can be used to
print displays or data from the commissioning operating area. You can use the <SELECT>
button to choose which of the installed printers should be used for output.
Default: Output as bitmap file
Editor
This key opens the ASCII editor in which files can be edited at Windows level.
You can select existing drives via the vertical softkeys.
See also
Configuring user alarms (Page 86)
HMI Advanced (IM4)
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
This alarm occurs if the HMI program is started for the first time and the
NCK/PLC has not yet finished booting or if communication with these
components is faulty.
When this alarm occurs, all display values connected with NCK/PLC
become invalid. Such faults are normal while the controls are starting up
(e. g. after resetting).
The alarm disappears automatically as soon as the fault situation is
resolved. If this alarm persists, the cause of the fault may be one of many
(for example, wire break, NCK/PLC has not booted, incorrect
address/baudrate configuration, ... ).
--
Introduction
1.2 Booting
9