Tool management
6.1 Setting tool management parameters on the HMI
Locations
Name
Display text
Number
Type
Index
Number
Overview
Note
The sequence must be adhered to when entering the buffer. The spindles must always be
entered first. A number is assigned internally for each buffer location, via which the buffer
location is addressed.
The buffer "spindle" with index 1 and spindle_1 in the NC have a direct relationship to one
another. This means that for example the "spindle" buffer with index 1 must also be the 1st
spindle for the NC, index 2 = 2nd spindle.
Creating a buffer location
Follow the steps outlined below:
1. Press the "New" softkey.
2. Enter a name: e.g. Gripper_1. If it exists, the display text is immediately displayed from
3. Select the type: Transfer location, gripper, loader, spindle
4. The buffer location is created by pressing "OK", the location number and the index are
Assigning / deassigning a spindle:
1. The "Assign spindle" softkey assigns a buffer location (e.g. gripper) to a spindle. This
2. The "Deassign spindle" softkey cancels an existing spindle assignment.
3. Assigning/removing buffer locations to/from the magazines
4. When a magazine is selected, the distance to the change position must be entered. At
5. The "Deassign magazine" softkey cancels an existing assignment of a buffer location to a
172
Enter or select the name of the buffer.
Language-dependent name of the magazine
If it exists, the display text is immediately displayed from patm_xx.ini.
Display of the current magazine number
Selection of buffer type (spindle/toolholder, gripper, transfer location, loader)
The index counts the locations of a type.
Display of the consecutive internal number under which the location is to be
addressed
The number of all buffer locations is displayed as a graph.
In addition, the currently selected buffer location (No.) is highlighted. Each "type"
is displayed in a different color.
patm_xx.ini.
internally assigned and incremented.
informs the software of the mechanical relation between the gripper and spindle.
least 0 must be entered, as otherwise the tool cannot be transported to this buffer
location. The "Assign magazine" softkey assigns the buffer location to the magazine.
magazine.