Installing the SV8100 Blades
G
S
1
ENERAL
ECTION
This chapter contains information to help the technician install the blades
for the UNIVERGE SV8100 system. The technician should be familiar with
this section before installing any equipment.
1.1
System Hardware Manual
I
NFORMATION

Slot Locations

Each CHS2U-US has six slots. In the Controlling Chassis, the
CD-CP00-US (for Key Systems) must be installed in the first slot
(slot 1). In the CHS2U GW-US and CHS2U B-US, the
CD-CP00-US must be installed in the first slot (slot 1).
Slot Locations in the CHS2U-US (19" Controlling Chassis):
Slot 1 – dedicated for the CPU
Slots 2~6 – universal
Slot Locating in the CHS2U-US (19" Expansion Chassis):
Slots 1~6 are universal. (i.e., any type of blade except the CPU
can be installed in these slots).
Slot Locations in the CHS2U GW-US and CHS2U B-US Base
(9.5" Chassis):
Slot 1 – CPU
Slots 2 and 3 – universal
Slot Locations in the 9.5" CHS2U B-US and CHS2U E
(Controlling Chassis with CPU):
Slot 1 – CPU
Slots 2~6 – universal
Slot Locations in the 9.5" CHS2U B-US and CHS2U E
(Expansion Chassis no CPU):
Slots 1~6 – universal