To avoid damage, the chassis should not be placed on unstable surfaces.
Although it is recommended to install the blades with the system power off,
all blades can be installed hot, except for the following:
CD-CP00-US
PZ-BS10 and PZ-BS11

Surveying the Customer Site

In most cases, a survey of the customer site is necessary to determine the
proper placement of the Main Distribution Frame (MDF), the exact dimensions
of the area selected for the MDF, cabling requirements, and possible
Intermediate Distribution Frame (IDF) locations.
The information obtained at the customer site can permit the installer to
partially assemble the MDF before installation at the customer premise. This
can reduce the time spent installing at the customer site and reduce
downtime.

Selecting the Best Location for Proper Installation

2.3.1

Selecting the Chassis Installation Site

When selecting an installation site for the chassis, consider the
following conditions to ensure proper installation:
Chassis are normally rack mounted to protect against accident
or flooding.
The chassis should not be located directly beneath pipes.
Leaks or condensation could damage the UNIVERGE SV8100
system equipment.
The area where the chassis is located must be free of corrosive
and inflammable gases, excessive chemical or industrial dusts,
and other materials that could cause a hazard to personnel or
to the proper functioning of the equipment.
The operating ambient temperature and humidity must be
within the limits specified in
page 2-30
The operation of the system is virtually noiseless and allows
wide selection of installation sites. Take care to ensure the
chassis or cabling does not present a hazard to office traffic. To
minimize cabling costs, a centralized location must be chosen.
Locate the chassis at a site where a dedicated AC power
source can be easily accessed.
6.3 Environmental Conditions on
in Chapter 2 System Specifications.