UNIVERGE SV8100
E
S
6
XTERNAL
ECTION
6.1
System Hardware Manual
The PGD(2)-U10 ADP provides amplifiers for each
page output port (for a maximum of +8 dBM, 600
ohms at 1KHz). No additional page amplification is
provided by the PGD(2)-U10 ADP but, if required,
an external page amplifier can be used for additional
amplification.
The page output of the CD-CP00-US does not
provide amplification (for a maximum output of -3
dBm, 600 ohms at 1KHz). If the paging volume is not
satisfactory using the CN8 or CN9 connector on the
CD-CP00-US, the PGD(2)-U10 ADP should be used
instead.
P
AGING AND

External Page Relays

Two external dry contact relays are available when a PGD(2)-U10 ADP is
installed which can be used to activate ancillary devices (i.e. door unlock
devices). The CD-CP00-US also provides one page relay. When the relay on
the PGD(2)-U10 ADP is used, there is no need to assign the relay to the Door
Box – connect the relay as detailed in the steps below for the Door Box used.
The relays on the PGD(2)-U10 ADPs are numbered 5~8. Each Door Box/
external page circuit provides a dry relay contact.
If Relays 5 and 6 of a PGD(2)-U10 are set as General
Purpose Relays, they cannot be used for Door Box/Page
Relays.
Program 10-21-05 sets the relay switch on the
CD-CP00-US.
If General Purpose Relay is set to 1 (Relay 1), the page
relay cannot function on the CD-CP00-US. General
Purpose Relays override Paging Relays and the Paging
Relay is associated with Relay 1 on CN10.
The service codes indicated are the default codes. Refer to Program
11-12-20 and 11-12-50 to redefine these codes as needed.
D
B
/P
OOR
OX
AGE
Issue 2.0
R
ELAYS
9 - 17