To perform a system software and firmware upgrade:
1.
Turn the system power off.
2.
After the system powers down, insert the USB Memory
containing the software upgrade into the USB port on the
CD-CP00-US.
3.
Push in and hold the Load button.
4.
Turn the system power on.
5.
Continue holding the Load button for approximately 10
seconds or until Status LED5 begins flashing red.
6.
Release the Load button.
7.
Wait until the Status LEDs on the CD-CP00-US have the
following indications (approximately two minutes):
LED 2: Flashing Red
LED 3: Flashing Red
LED 4: Flashing Red
LED 5: Steady Red
8.
Turn the system power off and remove the USB Memory.
9.
Turn the system power back on.
10.
When the system has completed reloading the software, the
Status LED begins flashing on the CD-CP00-US. The
remaining four LEDs are off.
To confirm the new software version is installed, press the
FEATURE + 3 keys on any display multiline terminal to view the
system version number.
The existing system software in the flash memory is replaced,
but the customer data (stored in the RAM) is saved.
Issue 2.0