Saving Your Configuration - NEC Univerge SV8100 System Hardware Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Issue 2.0
4 - 12
As the system recognizes the extension devices
automatically, when replacing the connected device, it must
be undefined in Program 10-03 prior to connecting the new
device. For example, if a port was previously used for a
telephone and a DSS Console is to be installed in that same
port, the telephone must first be undefined in Program 10-03
before the console is connected.
2.6.3.4

Saving Your Configuration

When programming is completed, to exit out of the program
option and save changes to the CD-CP00-US:
1. Press EXIT to exit the program options, if needed.
2. Press Speaker.
Saving System Data is displayed if changes were made
to system programming.
3. The display shows Complete Data Save when
completed and the telephone becomes idle.
2.6.3.5
Backing Up/Restoring a Database
As a precaution, it is recommended that the customer
database be saved prior to updating the system software.
There are two methods to save the database – either use
the PCPro application or save directly to USB Memory on
CD-CP00-US. Using PCPro, download the database and
save the file on the PC hard drive. To save the database
using a blank USB Memory, insert the USB Memory into the
USB Port on the CD-CP00-US blade and, using Program
90-03, save the software. Due to the file naming structure,
note that a USB Memory can hold only one customer
database (each database is saved to a directory called
DATA – this directory is overwritten if a second database is
saved to the same card). Each database to be saved
requires its own separate card (unless you choose to
rename the directory after it is saved, then rename it back to
DATA when you need to access the database).
If the customer data needs to be reloaded, the method for
restoring the database is determined by how the database
was saved. Using PCPro, the customer database is
uploaded using the Upload option in the application. If the
database is stored on a USB Memory, use Program 90-04,
with the database to be restored installed in the USB Port on
the CD-CP00-US blade.