4.
Remove the compiler paddle module,
2
Remove 2
1
screws
Disconnect the paddle
module cable connectors,
remove 2 screws and
pass the connector
assembly through the
frame aperture
3
Remove 2 screws
and ground strap
4
Manoeuvre the module
downwards, Remove the
module through the stapler
aperture
Figure 1 Paddle module attachment
Replacement
Do not damage or strain the paddle module ribbon cables or connectors
1.
Reverse the removal procedures to replace the compiler paddle module.
2.
Use the correct screws to secure the compiler paddle module; do not overtighten
Repairs/Adjustments
REP 11.49-171, REP 11.50-171
Figure
1.
CAUTION
REP 11.50-171 BM Exit Sensor
Parts List on
PL 11.168
Removal
Switch off the electricity to the machine. Refer to
from the customer supply while performing tasks that do not need electricity. Electricity
can cause death or injury. Moving parts can cause injury.
Take care during this procedure. Sharp edges may be present that can cause injury.
1.
Remove the BM right hand cover,
2.
Remove the upper static eliminator (3 screws),
3.
Figure
1, remove the BM exit sensor.
Replacement
Reverse the removal procedure to replace the BM exit sensor.
GP
6.
May 2013
4-344
WARNING
GP
14. Disconnect the power cord
WARNING
REP
11.56-171.
PL 11.168 Item
18.
2
Disconnect
the harness
and remove
the sensor
1
Remove the
screw then slide
out the sensor
Figure 1 Sensor removal