REP 11.65-171 Buffer Feed Motor
Parts List on
PL 11.150
Removal
Switch off the electricity to the machine. Refer to
from the customer supply while performing tasks that do not need electricity. Electricity
can cause death or injury. Moving parts can cause injury.
Take care during this procedure. Sharp edges may be present that can cause injury.
1.
Remove the rear cover
REP
11.1-171.
2.
Remove the buffer feed motor and bracket assembly,
Tension Spring
Figure 1 Buffer feed motor and bracket
3.
Remove 2 screws and the grounding wire to remove the motor and damper from the
bracket.
Replacement
1.
Reverse the removal procedures to replace the buffer feed motor.
2.
Fit the pivot screw and set the belt tension,
bracket screws fully until the belt is tensioned by the spring.
Xerox® WorkCentre® 5790 Family
WARNING
GP
14. Disconnect the power cord
WARNING
Figure
1.
1
Remove the
pivot and 2
bracket screws
2
Disconnect the
motor PJ.
ADJ
11.10-171. Do not tighten the motor
REP 11.66-171 Exit Feed Motor 2
Parts List on
PL 11.150
Removal
Switch off the electricity to the machine. Refer to
from the customer supply while performing tasks that do not need electricity. Electricity
can cause death or injury. Moving parts can cause injury.
Take care during this procedure. Sharp edges may be present that can cause injury.
1.
Remove the rear cover,
REP
2.
Remove exit feed motor 2 and bracket assembly,
Tension Spring
Figure 1 Exit feed motor and bracket
3.
Remove 2 screws and the grounding wire to remove the motor and damper from the
bracket.
Replacement
1.
Reverse the removal procedures to replace exit feed motor 2.
2.
Fit the bracket pivot screw and set the belt tension,
May 2013
4-373
WARNING
GP
14. Disconnect the power cord
WARNING
11.1-171.
Figure
1.
1
Remove the
pivot and 2
bracket screws
2
Disconnect the
motor PJ.
ADJ
11.10-171.
Repairs/Adjustments
REP 11.65-171, REP 11.66-171