3.
Refer to
Figure
3, remove the following:
Output paper path drive gear.
Fuser drive gear.
Registration transport drive gear.
Developer drive gear.
Idler rolls
Remove the circlip
and the developer
drive gear.
Remove the circlip and
the registration transport
drive gear.
Figure 3 Remove drive gears and idlers
Replacement
The spring loaded belt tensioner,
Figure 1
Replacement is the reverse of the removal procedure.
If a new developer drive gear is installed, reset the developer count to zero in the HFSI feature
screen. Refer to
GP 17
High Frequency service Items.
Repairs/Adjustments
REP 4.3, REP 4.4
Remove the
circlip, paper
path drive gear
and spring.
Remove the circlip and
Remove the
the fuser drive gear.
idler rolls.
CAUTION
is a floating type and should not be locked down.

REP 4.4 Photoreceptor Drive Gear

Parts List on (35-55 ppm)
Removal
Switch off the electricity to the machine,
customer supply while performing tasks that do not need electricity. Electricity can
cause death or injury. Moving parts can cause injury.
Take care during this procedure. Sharp edges may be present that can cause injury.
1.
Remove rear cover,
PL 8.10 Item
When the drive gear is removed from the shaft, the dowel pin may drop onto the IOT PWB or
LVPS.
2.
Remove the photoreceptor drive gear,
1
2
Remove three short
Remove the screw
and collar.
screws and the flywheel.
Figure 1 Photoreceptor drive gear
May 2013
4-42
PL
4.15, (65-90 ppm)
PL
4.10.
WARNING
GP
14. Disconnect the power cord from the
WARNING
1.
CAUTION
Figure
1.
3
Remove the drive gear
and the dowel pin.