Rep 5.2 Top Access Cover Assembly - Xerox WorkCentre 5790 Series Service Manual

Table of Contents

Advertisement

REP 5.2 Top Access Cover Assembly

Parts List on
PL 5.20
Removal
Switch off the electricity to the machine,
customer supply while performing tasks that do not need electricity. Electricity can
cause death or injury. Moving parts can cause injury.
1.
Open the DADH top cover.
2.
Remove the DADH rear cover,
PL 5.10 Item
3.
Remove the DADH top cover assembly,
4.
Remove the DADH top access cover assembly,
3
Remove the top
access cover
assembly.
Figure 1 Top access cover assembly
Repairs/Adjustments
REP 5.2
WARNING
GP
14. Disconnect the power cord from the
1.
REP
5.1.
Figure
1.
2
Remove the screw and
the bracket.
1
Disconnect PJ191 and
the ground harness.
Replacement
Be careful when the self tapping screw is installed into a plastic component, refer to
The replacement is the reverse of the removal procedure. Make sure that the 2 springs on the
idler roll are in the correct position,
CVT idler roll torsion
spring
May 2013
4-52
CAUTION
Figure
2. Then install the top cover.
Takeaway idler roll
torsion spring
Figure 2 Torsion springs
Xerox® WorkCentre® 5790 Family
GP
6.