Table 7 NVM chain 8
Location NVM Name
NVM Description
08-225
Inv Mot Rev Dup
NVM inverter motor reverse
Mot M6
to duplex motor speed up
for mode 6. Envelope pitch
simplex.
08-226
Rst Dup Jam Win-
Restart sheet to duplex jam
dow M1
window to indicate LE of the
sheet is late in mode 1.
08-227
Rst Dup Jam Win-
Restart sheet to duplex jam
dow M2
window to indicate LE of the
sheet is late in mode 2.
08-228
Rst Dup Jam Win-
Restart sheet to duplex jam
dow M5
window to indicate LE of the
sheet is late in mode 5.
Transparencies pitch mode
1 simplex.
08-229
Rst Dup Jam Win-
Restart sheet to duplex jam
dow M6
window to indicate LE of the
sheet is late - Envelope
pitch simplex only.
08-230
Inv Mot Slow Down
Inverter motor slow down
M1
for mode 1. Delay from
invert motor start ramp
down from high speed to
restart in opposite direction.
08-231
Inv Mot Slow Down
Inverter motor slow down
M2
for mode 2. Delay from
invert motor start ramp
down from high speed to
restart in opposite direction.
08-232
Inv Mot Slow Down
Inverter motor slow down
M3
for mode 3. Delay from
invert motor start ramp
down from high speed to
restart in opposite direction.
08-233
Inv Mot Slow Down
Inverter motor slow down
M4
for mode 4. SEF heavy-
weight invert only pitch
mode 2.
General Procedures/Information
dC131a
Value
Default
Location NVM Name
0 to 200ms
35 ppm =0,
08-234
40-55 ppm =0,
65-90 ppm =0
200 to 1500ms 35 ppm =1050,
40-55 ppm
08-235
=690,
65-90 ppm
=500
200 to 3000ms 35 ppm =2010,
40-55 ppm
08=236
=1340,
65-90 ppm
=900
08-237
200 to 3000ms 35 ppm =1050,
40-55 ppm
08-238
=690,
65-90 ppm
=500
200 to 1500ms 35 ppm =1050,
40-55 ppm
08-239
=690,
65-90 ppm
=500
0 to 1000ms
35 ppm =100,
08-240
40-55 ppm
=100,
65-90 ppm
=100
0 to 1000ms
35 ppm =100,
08-241
40-55 ppm
=100,
65-90 ppm
08-242
=100
0 to 1000ms
35 ppm =100,
40-55 ppm
=100,
08-243
65-90 ppm
=100
0 to 1000ms
35 ppm =100,
40-55 ppm
08-244
=100,
65-90 ppm
=100
May 2013
6-86
Table 7 NVM chain 8
NVM Description
Inv Mot Slow Down
Inverter motor slow down
M5
for mode 5. Transparencies
pitch mode 1 simplex.
Inv Mot Slow Down
Inverter motor slow down
M6
for envelopes mode 6 -
envelopes pitch simplex.
Lead Edge Thresh-
NVM Lead edge threshold. 1
old
Trail Edge Thresh-
NVM Trail edge threshold.
hold
Inv Mot on Fwd
Inverter motor on forward.
Use on 65-90 ppm only for
A6 media.
Eng Nip To Mov
Engages nips to move
Sheet
sheet into inverter path.
Inv Mot On Rev
Inverter motor on reverse
Open
until open.
Inv Mot FwdStop
Time for inverter motor to
Rev
go forward, then stop, then
to reverse.
Le Fsri Inv Mot On
Time to turn on inverter
dup
motor after LE leaves fuser
(duplex).
Le Nip Closed Dup Time between trail edge
and nip closed (duplex).
Exit Sen To Ofset
Time from exit sensor to off-
Mot On
set tray motor on.
Value
Default
0 to 1000ms
35 ppm =100,
40-55 ppm
=100,
65-90 ppm
=100
0 to 1000ms
35 ppm =100,
40-55 ppm
=100,
65-90 ppm
=100
35 ppm =1,
40-55 ppm =1,
65-90 ppm =1
0 to 4
35-55 ppm =4,
65-90 ppm =1
0 to 1000ms
35 ppm =860,
40-55 ppm
=600,
65-90 ppm
=430
0 to 400ms
35 ppm =230,
40-55 ppm
=130,
65-90 ppm =10
100 to 340ms
35 ppm =230,
40-55 ppm
=180,
65-90 ppm
=140
36 to 80ms
35-55 ppm
=50,
65-90 ppm =66
0 to 1000ms
35 ppm =860,
40-55 ppm
=600,
65-90 ppm =0
0 to 400ms
35 ppm =230,
40-55 ppm
=130,
65-90 ppm =0
0 to 3000ms
35 ppm =0,
40-55 ppm =0,
65-90 ppm =0