GP 15 How to Set the Machine Configuration
Description
Use this procedure when a new IOT PWB has been installed or the message 'Machine Speed
Configuration Error' occurs.
Procedure
Perform the following:
1.
Enter
dC131
NVM location 03-005 System Install Phase. Set the value to 2.
2.
Exit diagnostics, then reboot the machine.
3.
Re-run the install wizard. When requested, input the relevant activation code.
NOTE: The activation code can be found on a label on the rear of the machine. A copier
only machine will have DC 57XX in the top right corner of the label, a multi-function
machine will have MF 57XX.
4.
Complete the final actions,
SCP
6.
Xerox® WorkCentre® 5790 Family
GP 16 How to Safely Lift or Move Heavy Modules
Purpose
Use this procedure when lifting or moving heavy modules.
Procedure
When removing heavy modules from the machine, the following instructions must be observed:
1.
Ensure that a suitable stable surface to support the module after removal is located in
close proximity to the machine.
NOTE: Other parts of the machine are not a suitable stable surface.
2.
Ensure that the height of the support surface is between 750mm and 1000mm (30 inches
and 39 inches).
3.
Ensure that there are no hazards or obstacles between the machine and the support sur-
face.
4.
If instructed to remove the module toward the rear of the machine and only one person is
available, the module must be removed while standing at the rear of the machine. If two
people are available, the module may be removed while standing at the front of the
machine.
5.
Two people are required if the module is to be lifted on to the floor or lifted from the floor.