Xerox WorkCentre 5790 Series Service Manual page 1494

Table of Contents

Advertisement

Table 13
Output Codes 06
Table 14
Output Codes 07
Table 15
Output Codes 08
Table 16
Output Codes 09
Table 17
Output Codes 10
Table 18
Output Codes 11
Table 19
Output Codes 12
Table 20
Output Codes 14
Table 21
Output Codes 20
Procedure
Do not press Exit before stopping any energized components. The UI may lock up and grey
out. If this occurs, switch off the machine,
power cord and switch on the machine
GP
1.
Enter Diagnostics,
GP
1.
2.
Select Diagnostics Routines.
3.
Select required dC routine category:
Copier Routines, 330 Component Control.
Fax dC Routines, 330 Component Control.
4.
Select and input the required codes as follows:
NOTE: After a fault condition it may be necessary to switch off the machine and switch on
the machine
(GP
14) for the codes to operate.
NOTE: To clear an incorrectly entered code and reset the Add Component button to
00.000, press the hard key C.
a.
From the component control
Input Components
tables, select and enter the appropriate code into the Add Component button, and
touch the button. This will add the component to the top of the Component Name
table list, and when the list is full; the addition of more components will cause com-
ponents to be deleted from the bottom of the list.
NOTE: Fax component control codes can only be energized one at a time.
b.
If a control code is not known, it can be selected from the list displayed when the
Find Component button is touched, as follows:
NOTE: The 'Find Component' button is not available if components are energized.
i.
Enter the chain number into the Chain: button. Touch the Chain button to dis-
play the control codes for that chain.
ii.
Use the scroll buttons to locate the required code, touch the Component Name
button to highlight it and touch Select.
iii.
Repeat as required to add components to the Component Name table.
iv.
Touch Save to save the selections to the Component Name table list and return
to the Component Control window.
5.
To energize a component or group of components:
a.
Touch the control code to highlight it.
b.
Touch Start.
General Procedures/Information
dC330
CAUTION
GP 14
and remove the power cord. Reconnect the
14.
tables and the
Output Components
c.
The status of the component is shown in the Status column i.e.:
i.
On
ii.
Off
iii.
High
iv.
Low
v.
A numeric value with up to four digits e.g. 0020.
6.
Touching a component in the component table and then touching Stop, stops that compo-
nent. To stop all components touch Stop All.
7.
Touching Exit closes the Component Control window.
8.
To exit diagnostics mode,
GP
May 2013
6-110
1, select the Call Close Out button.
Xerox® WorkCentre® 5790 Family

Advertisement

Table of Contents
loading