Table 9 NVM chain 10
Location NVM Name
NVM Description
10-122
Te PFs To Inv Mot
Time to turn off inverter motor
Off Dup
after TE leaves fuser
(duplex).
10-123
Fsr Range
Temperature range below
standby in which start print
can begin.
10-124
Te Inv Snr To Mot
Inverter motor off stop posi-
Of SmpS1
tion (simplex).
10-125
Te Inv Snr Inv Of
Time to turn off inverter motor
Dup Siz 1
after TE leaves inverter sen-
sor for sheets <185mm and
>216mm.
10-126
Web Advance
Web advance group banding
Group
select.
10-328
Standby Temp (2) Target temperature during
standby mode.
10-329
Run Temp (2)
Target temperature during
run mode.
10-330
Low Power Temp
Target temperature during
(2)
power save mode. The low
power simmer temperature is
determined by the Power
Save mode set in Tools.
10-342
101-120mm Ofsfet
Offset temperature required
(2)
on thermistor B for paper
width. Unsigned number in
NVM table (displayed on
GUI) to be converted to
signed number. by subtrac-
tion of 10 from table value.
i.e. 8 displayed in NVM is
equivalent to -2 degrees Cel-
sius
General Procedures/Information
dC131a
Value
Default
Location NVM Name
0 to 1200ms
35 ppm=740
10-343
40-55 ppm
=510,
65-90 ppm =0
10 to 30 deg C 35 ppm=30
40-55 ppm
=10
65-90 ppm
=28
0 to 800 ms
35 ppm=530
10-344
40-55 ppm
=360,
65-90 ppm
=200
200 to 1200ms 35 ppm=740
40-55 ppm
=510,
65-90 ppm
=295
1 = group 1
2
10-345
2 = group 2
3 = group 3
10 to 230 deg
35 ppm=190
C
40-55 ppm
=195,
65-90 ppm
=208
100 to 230 deg
35 ppm=185
C
40-55 ppm
=195,
10-346
65-90 ppm
=203
50 to 150 deg
35 ppm=85
C
40-55 ppm
=95,
65-90 ppm
=135
0 to 20
10
May 2013
6-100
Table 9 NVM chain 10
NVM Description
121-140mm Offset
Offset temperature required
(2)
on thermistor B for paper
width. Unsigned number in
NVM table (displayed on
GUI) to be converted to
signed number. by subtrac-
tion of 10 from table value.
i.e. 8 displayed in NVM is
equivalent to -2 degrees Cel-
sius
141-160mm Offset
Offset temperature required
(2)
on thermistor B for paper
width. Unsigned number in
NVM table (displayed on
GUI) to be converted to
signed number. by subtrac-
tion of 10 from table value.
i.e. 8 displayed in NVM is
equivalent to -2 degrees Cel-
sius
161-180mm Offset
Offset temperature required
(2)
on thermistor B for paper
width. Unsigned number in
NVM table (displayed on
GUI) to be converted to
signed number. by subtrac-
tion of 10 from table value.
i.e. 8 displayed in NVM is
equivalent to -2 degrees Cel-
sius
181-200mm Offset
Offset temperature required
(2)
on thermistor B for paper
width. Unsigned number in
NVM table (displayed on
GUI) to be converted to
signed number. by subtrac-
tion of 10 from table value.
i.e. 8 displayed in NVM is
equivalent to -2 degrees Cel-
sius
Value
Default
0 to 20
10
0 to 20
10
0 to 20
10
0 to 20
10