4.
Move the scan carriage to the position shown in
left end of the frame cut-outs, then mark the position of the half rate scan carriage. The
anchor balls should be in the position shown in
Scan carriage
Exposure lamp
Figure 2 Carriage start position
5.
(W/TAG
150) remove the document size sensor cover, refer to
6.
Remove the cable clamps, with captive screws, from the scan carriage. Move the cables
clear of the scan carriage, then lift the scan carriage out through the cut-outs in the frame.
Rest the scan carriage out of the way of the cables. It is not necessary to disconnect the
ribbon cable. Store the cable clamps for later use.
7.
Unhook the tension spring from the rear cable. Remove the spring from the cable and
store the spring for later use.
8.
Remove the rear cable completely by unhooking the end ball from its retaining bracket
and unwind the cable from the capstan.
9.
Repeat steps 7 and 8 for the front cable.
Xerox® WorkCentre® 5790 Family
Figure
2, with the exposure lamp at the
Figure
1.
Frame cut-out
Half rate scan
carriage
REP
14.20.
May 2013
Replacement
NOTE: The replacement procedure is made easy by holding the windings on the capstan in
place with tape at all times, until each cable is fully installed. Keep the cable tight to prevent it
unwinding.
1.
Prepare several short lengths of adhesive tape.
2.
If necessary, rotate the capstan to bring the anchor ball recess to the top and slightly to
the right. Check that the half rate scan carriage is in the start position, as in
3.
Place the rear cable in the position shown in
adhesive tape.
Front
Figure 3 Winding start position
4.
Starting with the end-ball end of the cable, wind on three turns, stopping at each turn to
hold the cable to the capstan with adhesive tape. If necessary, use a fresh length of adhe-
sive each time to ensure the cable is held tightly.
5.
Hold the capstans in position, then tape the top of the fly-wheel weight (W/O
the drive shaft
(W/TAG
150) onto the top left of the scanner frame. This is to prevent the
capstan turning while the cable end is placed in position.
4-419
Figure
Figure
3. Hold in place on the capstan with
Silver cable
rear
End ball
Dark cable
Repairs/Adjustments
REP 14.12
2.
TAG
150) or