Xerox WorkCentre 5790 Series Service Manual page 1493

Table of Contents

Advertisement

Hop count to device.
Procedure
1.
Enter diagnostics,
GP
1.
2.
Select, Network Routines, dC314 Network Connectivity Test.
3.
Touch the appropriate test button.
NOTE: The feature button is grayed out and disabled for unavailable protocols.
4.
Touch Start Test and follow the on-screen instructions.
Xerox® WorkCentre® 5790 Family
dC330 Component Control
Purpose
To show the status of input components e.g. sensors, and to energies and exercise output
components e.g. motors, solenoids.
Description
Output and input component codes are entered into the Component Control Table on the UI,
and then energized individually or in permitted groups. The codes in the tables are grouped in
function chain
(GP
2) order.
Go to the appropriate procedure:
Input Components
Output Components
Input Components
When the appropriate code is entered the status of the component will be shown on the UI.
NOTE: The logic level shown on the circuit diagrams with the signal name will be the actual
signal as measured with a service meter. This will not necessarily be the same as the logic
state shown on the UI, especially where the output is inverted. When testing components using
these control codes, look for a change in state, not for a high or low.
The displayed status of the input component can be changed by causing the component status
to change, e.g. operating a sensor with a sheet of paper. When a sensor is operated a beep
will sound.
Go to the appropriate table:
Table 1
Input codes 01
Table 2
Input Codes 05
Table 3
Input Codes 06
Table 4
Input Codes 07
Table 5
Input Codes 08
Table 6
Input Codes 09
Table 7
Input Codes 10
Table 8
Input Codes 11
Table 9
Input Codes 12
Table 10
Input Codes 14
Output Components
When the appropriate code is entered, the component will energize for a set time and then stop
to protect the components. The default time-out for most components is set at 90 s, but can be
as short as 5 s. Some components require that other components are energized at the same
time and it is possible to enter and energize up to six component control codes (not fax), but
only in permitted groups. If illegal combination of codes are entered the illegal codes will not
energize.
Go to the appropriate table:
Table 11
Output Codes 04
Table 12
Output Codes 05
May 2013
6-109
General Procedures/Information
dC314, dC330