Xerox WorkCentre 5790 Series Service Manual page 1116

Table of Contents

Advertisement

REP 11.69-171 Drive Coupling Assembly
Parts List on
PL 11.193
Removal
Switch off the electricity to the machine. Refer to
from the customer supply while performing tasks that do not need electricity. Electricity
can cause death or injury. Moving parts can cause injury.
Take care during this procedure. Sharp edges may be present that can cause injury.
1.
Remove the tri-folder rear cover,
REP
NOTE: Access is improved if the top cover is removed also.
Repairs/Adjustments
REP 11.69-171
WARNING
GP
14. Disconnect the power cord
WARNING
11.67-171.
2.
Remove the drive coupling assembly bracket,
5
Slacken the tensioner lock screw
then move the crease roll tensioner
pulley to the left. Tighten the lock
screw.
Figure 1 Drive coupling assembly
May 2013
4-378
Figure
1.
1
Remove the
drive belt.
2
Remove the
driven pulley and
gear.
3
Remove the feed and
the exit roll drive gear
then the bearing.
4
Remove 5 screws,
then the drive coupling
assembly bracket