Rep 7.29 Tray 5 Elevator Tray Guides - Xerox WorkCentre 5790 Series Service Manual

Table of Contents

Advertisement

REP 7.29 Tray 5 Elevator Tray Guides

Parts List on
PL 7.70
Removal
Switch off the electricity to the machine. Refer to
from the customer supply while performing tasks that do not need electricity. Electricity
can cause death or injury. Moving parts can cause injury.
Take care during this procedure. Sharp edges may be present can cause injury.
1.
Remove the tray assembly from the tray 5 module, refer to
to 11.
2.
Remove the infill plate assembly,
Figure
1
Retain the spring using
a thumb or finger
Figure 1 Infill plate assembly removal
3.
Separate the lift plate from the tray lift top cover,
Xerox® WorkCentre® 5790 Family
WARNING
GP
14. Disconnect the power cord
WARNING
REP 7.21
and perform steps 1
1.
3
Remove the assembly taking care
not to lose the spring
Figure
2.
1
Remove 5 screws
2
Remove 2
screws
4.
Remove the tray 5 elevator harness,
5.
Remove the elevator tray guides,
May 2013
4-111
Figure 2 Tray separation
Figure
3.
1
Remove the
ground screw
3
Release the harness
from the 5 retainers
4
Pass the terminals one at a time
through the frame hole and guide
Figure 3 Harness removal
Figure
4.
Repairs/Adjustments
2
Remove and turn
over the lift plate
2
Disconnect the
terminals
REP 7.29

Advertisement

Table of Contents
loading