Xerox WorkCentre 5790 Series Service Manual page 1472

Table of Contents

Advertisement

Table 7 NVM chain 8
Location NVM Name
NVM Description
08-265
TE Duplex
Trail edge detection duplex
sensor = paper size - NVM
from LE duplex sensor.
08-266
Pitch Win Rel Del
Pitch window release delay. 0 to 1000ms
08-267
Fin Finish Tim
Finisher finish time.
08-268
Fin Prep Tim
Finisher preparation time.
08-269
MSI Stray Sheet
Jam timer for stray sheets
from the bypass tray (MSI).
08-270
MSI Feed To PFM
Delay from the bypass tray
Feed
(MSI) feed to paper feed
module (PFM) feed to avoid
jam.
08-271
Inv Mot Rev To
Inverter motor reverse to
Stop Dup1
inverter motor stop duplex
1.
08-272
Inv Mot Rev To
Inverter motor reverse to
Stop Dup 2
inverter motor stop duplex
2.
08-273
Inv Mot Rev To
Inverter motor reverse to
Stop Dup 3
inverter motor stop duplex
3.
08-274
Inv Mot Rev To
Inverter motor reverse to
Stop Dup 4
inverter motor stop duplex
4.
General Procedures/Information
dC131a
Value
Default
Location NVM Name
0 to 1000ms
35 ppm =270,
08-275
40-55 ppm
=200,
65-90 ppm
=100
35 ppm =440,
08-276
40-55 ppm
=320,
65-90 ppm
=227
0 to 0
35 ppm =0,
08-277
40-55 ppm =0,
65-90 ppm =0
0 to 0ms
35 ppm =0,
40-55 ppm =0,
08-278
65-90 ppm =0
0 to 1000ms
35 ppm =0,
08-279
40-55 ppm =0,
65-90 ppm =0
0 to 1000ms
35 ppm =370,
40-55 ppm
=250,
08-280
65-90 ppm
=172
0 to 1000ms
35 ppm =628,
40-55 ppm
=343,
08-281
65-90 ppm
=500
0 to 1000ms
35-55 ppm
=188,
65-75 ppm
=219,
08-282
65-90 ppm
=179
08-283
0 to 1000ms
35 ppm =410,
40-55 ppm
08-284
=414,
65-90 ppm
08-286
=365
10 to 2000ms
35-55 ppm
08-287
=188,
65-75 ppm
=219,
08-288
90 ppm =179
May 2013
6-88
Table 7 NVM chain 8
NVM Description
Inv Mot Rev To
Inverter motor reverse to
Stop Dup 5
inverter motor stop duplex 5
(transparencies).
Inv Mot Rev To
Inverter motor reverse to
Stop Dup 6
inverter motor stop duplex 6
(envelopes).
Add To MSUI Pitch
Addition to normal bypass
Period
(MSI) pitch period.
Split Nip Control
Split nip control for 1st
S1
sheet.
Tim To Del Simp
IOT time to deliver simplex. 0 to 5000ms
Tim To Del Invet
IOT time to deliver: inter
(simplex + paper length).
Tim To Del Simp3
IOT time to deliver duplex
(simplex + 3 pitches).
Fsr 3min Warning
Temperature threshold
Temp
level.
Fsr 2min Warning
Temperature threshold
Temp
level.
Fsr 1min Warning
Temperature threshold
Temp
level.
Fsr Delta
Temperature difference
between the 2 thermistors.
Fsr TolrunA
Temperature tolerance
either side of run target tem-
perature. Thermistor A.
Fsr Tolsave
Temperature tolerance
either side of power save
target temperature.
Value
Default
0 to 1000ms
35 ppm=628,
40-55 ppm
=343,
65-90 ppm
=500
0 to 1000ms
35 ppm=628,
40-55 ppm
=343,
65-90 ppm
=500
0 to 1000ms
35-55 ppm=0
65 ppm=170
75 ppm=290
90 ppm=400
0 to 350ms
210
35 ppm=2814,
40-55 ppm
=1961,
65-90 ppm
=1429
0 to 5000ms
35 ppm=3218,
40-55 ppm
=2247,
65-90 ppm
=1710
0 to 5000ms
35 ppm=2814
40-55 ppm
=1961,
65-75 ppm
=1429,
90 ppm=1432
10 to 50 deg. C 40
40 to 100 deg.
60
C
60 to 120 deg.
90
C
0 to 0 deg. C
45
0 to 0 deg. C
20
0 to 0 deg. C
35-45 ppm=0
55-90 ppm=15