Table 7 NVM chain 8
Location NVM Name
NVM Description
08-207
Pitch Tick Dup
IOT paper path timing pitch
Mode 2
tick setting - Duplex mode
2.
08-208
Pitch Tick Dup
IOT paper path timing pitch
Mode 3
tick setting - Duplex mode
3.
08-209
Pitch Tick Dup
IOT paper path timing pitch
Mode 4
tick setting - Duplex mode
4.
08-210
Pitch Tick Dup
IOT paper path timing pitch
Mode 5
tick setting - Duplex mode
5.
Transparency pitch mode 1
simplex.
08-211
Pitch Tick Dup
IOT paper path timing pitch
Mode 6
tick setting - Duplex mode
6.
08-212
Restart Dup M5
IOT transparency timing
Txpar
restart sheets into duplex
for mode 5. Transparency
pitch mode 1 simplex.
08-213
Restart Dup M6
IOT envelopes timing
Envelope
restart sheets into duplex
for mode 6.
Envelope pitch mode 1.
08-214
Nip Open Inv Mot
Time for nip to open after
Rev M1
inverter motor starts to
reverse (duplex for mode
1).
Xerox® WorkCentre® 5790 Family
Value
Default
Location NVM Name
1000 to 3500
35 ppm =2390,
08-215
40-55 ppm
=1670,
65-75 ppm
=1220,
90 ppm =1110
08-216
1000 to 3500
35 ppm =2760,
40-55 ppm
=1930,
65-75 ppm
=1430,
08-217
90 ppm =1290
1000 to 3500
35 ppm =2390,
40-55 ppm
=1670,
65-75 ppm
08-218
=1220,
90 ppm =1110
600 to 3500
35 ppm =1560,
40-55 ppm
=1090,
08-219
65-75 ppm
=800,
90 ppm =690
1000 to 3500
35 ppm =1560,
40-90 ppm
08-220
=1090
0 to 2500ms
35 ppm =1331,
40-55 ppm
08-221
=927,
65-75 ppm
=985,
90 ppm =697
0 to 2500ms
35 ppm =1331,
08-222
40-55 ppm
=927,
65-75 ppm
=985,
90 ppm =697
08-223
10 to 1000ms
35 ppm =570,
40-55 ppm
=400,
65-90 ppm
=240
08-224
May 2013
6-85
Table 7 NVM chain 8
NVM Description
Nip Open Inv Mot
Time for nip to open after
Rev M2
inverter motor starts to
reverse (duplex for mode
2).
Nip Open Inv Mot
Time for nip to open after
Rev M3
inverter motor starts to
reverse (duplex for mode
3).
Nip Open Inv Mot
Time for nip to open after
Rev M4
inverter motor starts to
reverse (duplex for mode
4). SEF Heavyweight invert
only pitch.
Nip Open Inv Mot
Time for nip to open after
Rev M5
inverter motor starts to
reverse (duplex for mode 5)
transparencies. Transpar-
ency pitch mode 1 simplex.
Nip Open Inv Mot
Time for nip to open after
Rev M6
inverter motor starts to
reverse (duplex for mode
6). Envelopes pitch simplex
only.
Inv Mot Rev Dup
NVM inverter motor reverse
Mot M1
to duplex motor speed up
for mode 1.
Inv Mot Rev Dup
NVM inverter motor reverse
Mot M2
to duplex motor speed up
for mode 2.
Inv Mot Rev Dup
NVM inverter motor reverse
Mot M3
to duplex motor speed up
for mode 3.
Inv Mot Rev Dup
NVM inverter motor reverse
Mot M4
to duplex motor speed up
for mode 4. SEF Heavy-
weight invert only pitch
mode 2.
Inv Mot Rev Dup
NVM inverter motor reverse
Mot M5
to duplex motor speed up
for mode 5 transparencies
pitch mode 1 simplex.
Value
Default
10 to 1600ms
35 ppm =1300,
40-55 ppm
=900,
65-90 ppm
=240
10 to 2000ms
35 ppm =1300,
40-55 ppm
=900,
65-90 ppm
=640
10 to 1600ms
35 ppm =1300,
40-55 ppm
=900,
65-90 ppm
=640
10 to 1000ms
35 ppm =570,
40-55 ppm
=400,
65-90 ppm
=240
10 to 1000ms
35 ppm =570,
40-55 ppm
=400,
65-90 ppm
=240
0 to 200ms
35 ppm =0,
40-55 ppm =0,
65-90 ppm =0
0 to 2000ms
35 ppm =1180,
40-55 ppm
=820,
65-90 ppm
=550
0 to 2000ms
35 ppm =1760,
40-55 ppm
=1230,
65-90 ppm
=550
0 to 2000ms
35 ppm =1180,
40-55 ppm
=820,
65-90 ppm
=550
0 to 200ms
35 ppm =0,
40-55 ppm =0,
65-90 ppm =0