REP 7.18 Tray 5 Down Limit Switch
Parts List on
PL 7.70
Removal
Switch off the electricity to the machine,
customer supply while performing tasks that do not need electricity. Electricity can
cause death or injury. Moving parts can cause injury.
Take care during this procedure. Sharp edges may be present that can cause injury.
1.
The tray needs to be positioned in the middle of its travel. If the tray must be repositioned,
refer to
REP
7.16. Disengage the elevator motor from the tray and move the tray to the
required position. Re-engage the elevator motor to hold the tray.
2.
Remove the tray lift top cover,
Figure
2
Remove the tray lift top cover.
Figure 1 Paper tray release
Repairs/Adjustments
REP 7.18
WARNING
GP
14. Disconnect the power cord from the
WARNING
1.
1
Remove
three screws.
3.
Remove the tray 5 down limit switch,
1
Disconnect the harness.
Figure 2 Remove tray 5 down limit switch
Replacement
1.
The replacement is the reverse of the removal procedure. Refer to
the screws.
2.
Check that the wires are not trapped when refitting the tray lift top cover.
May 2013
4-96
Figure
2.
2
3
Remove two screws.
Remove the switch
Xerox® WorkCentre® 5790 Family
GP 6
before refitting