DIAGNOSIS USING THE MANIFOLD GAUGE

On normal operation during the cooling cycle, the
manifold gauge must indicate approximately 1.5 - 2.0
kg/cm
2
at low pressure side and 14.5 - 15 kg/cm
high pressure side, on condition that the temperature
at the cooler inlet, 30 º C - 35 º C, 2,000 rpm of the
engine rpm , full cold and maximum blower speed.
Symptom
1. High and low pressure are abnormally low.
2. Air at cooler outlet is not cold.
1. High and low pressure are abnormally high.
1. High and low pressure are abnormally high.
2. Connection at the low pressure is not cold.
SSANGYONG Y200
2
at
Cause
There is a gas leak in the
cooling system.
YAD7B080
Insufficient cooling and
faulty condenser cooling
by excessive
refrigerant.
YAD7B090
Belt is slipped
There is an air in the
cooling system
YAD7B100
GENERAL HVAC SYSTEM 7B-11
Action
Check the oil leak,
repair
Add the refrigerant
Keep the specified
amount of the
refrigerant, Clean the
condenser
Repair the belt
Clean and repair the
receiver-drier
Check the oil
contamination etc.