5D2-70 TRANSFER CASE - TOD
yyyy
yyyy

TOD CONTROL UNIT

Removal & Installation Procedure
1. Disconnect (-) cable from battery.
2. Pull toward the driver seat and disconnect the 30
pin connector from TOD control unit.
YAD5D280
3. Unscrew 2 bolts.
YAD5D290
4. Installation should follow the removal procedure
in the reverse order.
Notice: When replace TOD control unit, it is
required to make a coding correspondent with
vehicle specification.
Installation Notice
Tightening Torque
YAD5D300
SHIFT MOTOR
Removal & Installation Procedure
1. Disconnect (-) cable from battery.
2. Disconnect shift motor/magnetic clutch coil
connector (black pin7) upper backside.
3. Unscrew 3 shift motor mounting bolts (M10).
4. Unscrew a bracket mounting bolt (M10).
Notice: When disconnecting shift motor and
mounting bracket, it is required to unscrew 2 units
of adjusting bolts (M10) form motor and bracket.
YAD5D310
10 N•m (89 lb-in)