Diagnosis - SSANGYONG Y200 Manual

Hide thumbs Also See for Y200:
Table of Contents

Advertisement

8B-12 RESTRAINTS
Possible Cause
Does the warning lamp
Ignition "ON"
blink at seven times for
Check warning
7 seconds and then turn
lamp on I/P
off?
Does the fault code
display on the scan tool
display?
Is there any open in
fuse?
Is there any short in
fuse?
Is there any short in
wiring?
Is there any open in
wiring?
Does the voltage
indicate 11~14V?
Is there any open or
short in wiring?
Is there any open or
short in wiring?

DIAGNOSIS

Yes
System OK
No
Connect the scan tool to diagnostic connector (ALDL).
Select the fault code display menu and clear code
menu.
Yes
Perform "Diagnostic System Check".
No
Check any fuse open.
Yes
Replace fuse.
No
Disconnect wiring connector.
Check any wiring short between fuse and wiring
connector.
Yes
Repair wiring.
No
Disconnect SDM wiring connector.
Check wiring short between connector terminal and
SDM connector terminal.
Yes
Replace airbag wiring.
No
Check any open between ALDL connector No.4, No.5
terminal and ground.
Yes
Repair wiring
No
Ignition "ON"
Measure voltage at the cigar lighter socket.
Yes
Check any open or short between ALDL connector
terminal and wiring connector terminal.
No
Repair the wiring of the cigar lighter socket.
Yes
Repair wiring
No
Check any open or short between SDM connector
terminal and wiring connector terminal.
Yes
Replace the airbag wiring.
No
Replace the SDM.
Action
SSANGYONG Y200

Advertisement

Table of Contents
loading

Table of Contents