Inspect the wiring for poor electrical connections
at the TCM and at the 10-way transmission
connector. Look for possible bent, backed out,
deformed or damaged terminals. Check for weak
terminal tension as well. Also check for chafed wires
that could short to bare metal or other wiring.
Inspect for broken wire inside the insulation.
If diagnosing for a possible intermittent short or
open condition, move or massage the wiring
harness while observing test equipment for a
change.
Solenoid Logic for Static Gear States
Gear
S1
st
1
ON
n d
2
OFF
r d
3
OFF
th
4
ON
OFF
Reverse
OFF
Neutral
Park
OFF
Step
Perform a Transmission Control Module (TCM)
1
Diagnostic System Check.
Is the check performed?
1. Install the scan tool.
2. Turn the ignition ON, with the engine OFF.
3. Record and then clear DTCs.
2
4. Operate the vehicle within the conditions for
setting this DTC as specified in the text.
Does the scan tool display P1734?
1. Turn the ignition OFF.
2. Disconnect the 10-way transmission connector.
(additional DTCs will set)
3. Connect Solenoid/Thermistor Electrical Tester
(STET) to the 10-way transmission connector of
3
transmission side and to the good ground.
4. Turn the mode knob of STET to 2 and push the red
button.
Does the bulb of open circuit on the solenoids side of
STET illuminate?
1. Remove the valve cover. Refer to the Transmission
in this section.
2. Check the wiring harness from 10-way transmission
4
connector to Solenoid 2 (S2) on the valve body for an
open or short to positive and repair as necessary.
Is a repair necessary?
Check the S2 necessarycircuit for an open and repair
as necessary.
5
Is a repair complete?
SSANGYONG Y200
S2
ON
ON
OFF
OFF
OFF
OFF
OFF
DTC P1734 Solenoid 2 Circuit Open
Action
AUTOMATIC TRANSMISSION 5A-109
Test Description
The number(s) below refer to the step number(s) on
the Diagnostic Table.
3. Checks if the S2 circuit in the transmission is mal-
functioning.
4. Check cable in the transmission for open / short.
6. Check resistance between S2 terminal A and B.
Standard value is 22 - 30 Ω.
9. Check connections of other connectors
Value(s)
-
Go to Step 2
-
Go to Step 3
-
Go to Step 4
-
Go to Step 11
-
Go to Step 11
Yes
No
Go to "TCM
Diagnostic
System Check"
Go to
"Diagnostic
Aids"
Go to Step 8
Go to Step 5
Go to Step 6

Advertisement