SSANGYONG Y200 Manual page 1248

Hide thumbs Also See for Y200:
Table of Contents

Advertisement

If diagnosing for a possible intermittent short or
open condition, move or massage the wiring
harness while observing test equipment for a
change.
Test Description
The number(s) below refer to the step number(s) on
the Diagnostic Table.
3. Checks if the S6 circuit in the transmission is mal-
functioning.
Step
Perform a Transmission Control Module (TCM) System
Check.
1
Is the check performed?
1. Install the scan tool.
2. Turn the ignition ON, with the engine OFF.
3. Record and then clear DTCs.
4. Operate the vehicle within the conditions for
2
setting this DTC as specified in the text.
Does the scan tool display P1746?
1. Turn the ignition OFF.
2. Disconnect the 10-way transmission connector.
(additional DTCs will set)
3. Connect Solenoid/Thermistor Electrical Tester
(STET) to the 10-way transmission connector of
3
transmission side and to the good ground.
4. Turn the mode knob of STET to 6 and push the red
button.
Does the bulb of close circuit on the solenoids side of
STET illuminate?
1. Remove the valve cover. Refer to the Transmission
in this section.
2. With a test light connected to B+, probe the wiring
4
harness from 10-way transmission connector to
Solenoid 6 (S6) on the valve body.
Does the test light illuminate?
Repair the short to ground in the wiring harness.
5
Is the repair complete?
Using a Digital Volt Meter (DVM), measure the
resistance between S6 terminal A and B.
6
Is the resistance within the specified value?
Replace the S6.
7
Is the action complete?
1. Disconnect the TCM connector B.
2. With a test light connected to B+, probe the wiring
8
harness from 10-way transmission connector
terminal 6 to TCM terminal B12.
Does the test light illuminate?
Check for a poor connection at the 10-way transmission
connector and TCM connector and repair the
9
malfunctioning terminals as necessary.
Is a repair necessary?
SSANGYONG Y200
DTC P1746 Solenoid 6 Circuit Short
Action
AUTOMATIC TRANSMISSION 5A-153
4. Check cable in the transmission for short to
ground.
6. Check resistance between S6 terminal A and B.
Standard value is 22 - 30 Ω.
9. Check connections of other connectors.
Value(s)
-
Go to Step 2
-
Go to Step 3
-
Go to Step 4
-
Go to Step 5
-
Go to Step 11
"Diagnostic
20 - 30 Ω
-
Go to Step 11
-
Go to Step 5
-
Go to Step 11
Yes
No
Go to "TCM
Diagnostic
System Check"
Go to
"Diagnostic
Aids"
Go to Step 8
Go to Step 6
-
Go to
Aids"
Go to Step 7
-
Go to Step 9
Go to Step 10

Advertisement

Table of Contents
loading

Table of Contents