Sign In
Upload
Manuals
Brands
Festo Manuals
Control Unit
CPX-FVDA-P2
Festo CPX-FVDA-P2 Manuals
Manuals and User Guides for Festo CPX-FVDA-P2. We have
6
Festo CPX-FVDA-P2 manuals available for free PDF download: Manual, Original Instructions Manual, Brief Description, Operating Instruction
Festo CPX-FVDA-P2 Manual (150 pages)
Terminal CPX Output module
Brand:
Festo
| Category:
Control Unit
| Size: 0.73 MB
Table of Contents
Table of Contents
5
Important User Information
8
General Safety Instructions
10
Intended Use
11
Rules for Product Configuration
12
Foreseeable Misuse
15
Attainable Safety Level
17
Failures Due to a Common Cause (Common Cause Failure - CCF)
17
Requirements for Product Use
18
Transport and Storage Conditions
20
Service
20
Range of Applications and Certifications
20
Product Identification
22
Information Regarding this Description
25
Product-Specific Terms and Abbreviations
26
System Overview CPX-FVDA-P2
31
Cpx Terminal with Output Module Cpx-Fvda-P2/Design of the Output Module Cpx-Fvda-P2
32
CPX Terminal with Output Module CPX-FVDA-P2
32
Design of the Output Module CPX-FVDA-P2
32
Required Bus Topology (Control Chain)
32
Profisafe
32
System Overview CPX-FVDA-P2
33
CPX Terminal with Output Module CPX-FVDA-P2
33
Profisafe Safety Profile
44
Profisafe
44
Process Image
45
Bit Pattern of the Output and Input Data (F-User Data)
46
Mode of Operation of the Output Module
52
Application Ranges
53
Application Examples
57
Requirements for Actuators (CH0
71
Electrical Requirements
71
Safety-Related Requirements
73
Installation
75
Table of Contents
76
General Installation Instructions
77
Installation
77
Connecting the Cables and Plugs to the Connection Block
79
Electrical Connection and Display Components
81
Pin Allocation with M12 Connection Block
82
Pin Allocation with Terminal Strip Connection Block
83
Set Profisafe Address
84
Dismounting and Mounting the Electronics Module
87
Dismounting the Electronics Module
88
Mounting the Electronics Module
89
Commissioning
91
Table of Contents
92
Commissioning
93
General Instructions
93
Device Master File (GSD/GSDML)
93
Preparing for Commissioning
95
Commissioning Steps
96
Setting the Profisafe Parameters
97
Setting the CPX Module Parameters
99
CPX Module Parameters CPX-FVDA-P2 in Detail
100
Parameterisation and Signal Display with the Operator Unit CPX-MMI-1
104
Configuration with Siemens STEP 7 (Example)
106
Operation
113
Operation
115
LED Status Indication
115
Diagnosis and Error Handling
117
Table of Contents
118
Diagnosis and Error Handling
119
Summary of Diagnostics Options
119
Possible Error Messages of the Output Module CPX-FVDA-P2
120
Diagnostics Via Leds
122
Error Handling and Parameterisation
125
Diagnostics Via the CPX Bus Node
128
Diagnostics with the Operator Unit CPX-MMI
128
Service, Repair, Disposal
129
Table of Contents
130
Maintenance
131
Repair
131
Service, Repair, Disposal
131
Disposal
132
A. Technical Appendix
133
Appendix A
134
Technical Appendix
135
Technical Data of the Output Module CPX-FVDA-P2
135
Technical Data of the Connection Blocks
141
Technical Data of the Interlinking Block
142
B. Index
144
Advertisement
Festo CPX-FVDA-P2 Manual (150 pages)
CPX terminal Output module
Brand:
Festo
| Category:
Control Unit
| Size: 0.96 MB
Table of Contents
Table of Contents
5
Important User Instructions
8
General Safety Instructions
10
Intended Use
11
Rules for Product Configuration
12
Foreseeable Misuse
15
Attainable Safety Level
17
Failures Due to Common Cause (Common Cause Failure - CCF)
17
Requirements for Product Use
18
Transport and Storage Conditions
20
Service
20
Range of Application and Certifications
20
Product Identification
22
Instructions on this Description
25
Product-Specific Terms and Abbreviations
26
System Overview CPX-FVDA-P2
31
System Overview Cpx-Fvda-P2
32
CPX Terminal with Output Module CPX-FVDA-P2
33
System Overview CPX-FVDA-P2
33
Design of the Output Module CPX-FVDA-P2
37
Required Bus Topology (Control Loop System)
44
Profisafe
45
Safety Profile Profisafe
45
Process Image
46
Bit Pattern of the Output and Input Data (F-User Data)
47
Mode of Operation of the Output Module
52
Application Ranges
53
Application Examples
57
Requirements for Actuators (CH0
71
Electrical Requirements
71
Safety-Oriented Requirements
73
Installation
76
General Instructions on Installation
77
Installation
77
Connecting the Cables and Plugs to the Connection Block
79
Electrical Connection and Display Components
81
Set Profisafe Address
84
Dismounting and Mounting the Electronics Module
87
Dismantling the Electronics Module
88
Mounting the Electronics Module
89
Commissioning
92
Commissioning
93
General Instructions
93
Device Master File (GSDML and GSD)
93
Preparing for Commissioning
95
Commissioning Steps
96
Set the Profisafe Parameters
97
Setting the CPX Module Parameters
99
CPX Module Parameters CPX-FVDA-P2 in Detail
100
Parameterisation and Signal Display with the Operator Unit CPX-MMI-1
104
Configuration with Siemens STEP 7 (Example)
106
Operation
115
Status Display Via Leds
115
Behaviour During the Switch-On Phase (Startup Phase)
116
Diagnostics and Error Handling
118
Diagnostics and Error Handling
119
Summary of Diagnostics Options
119
Possible Error Messages of the Output Module CPX-FVDA-P2
120
Diagnostics Via Leds
122
Error Handling and Parameterisation
125
Diagnostics Via the CPX Bus Node
128
Diagnostics with the Operator Unit CPX-MMI
128
Service, Repair, Disposal
130
Repair
131
Service
131
Service, Repair, Disposal
131
Disposal
132
Festo CPX-FVDA-P2 Original Instructions Manual (100 pages)
Output module
Brand:
Festo
| Category:
Control Unit
| Size: 2.81 MB
Table of Contents
Table of Contents
3
1 General Safety Instructions
6
Important User Information
6
Danger Categories
6
Marking of Special Information
6
General Safety Instructions
7
Intended Use
7
Rules for Product Configuration
8
Foreseeable Misuse
10
Attainable Safety Level
11
Failures Due to a Common Cause (Common Cause Failure - CCF)
11
Requirements for Product Use
12
Technical Prerequisites
12
Training of Skilled Personnel
12
Transport and Storage Conditions
13
Service
13
Range of Application and Certifications
13
Product Identification
13
Revision Version
14
Manufacturing Period
15
Information Regarding this Description
15
Product-Specific Terms and Abbreviations
16
2 System Overview CPX-FVDA-P2
20
CPX Terminal with Output Module CPX-FVDA-P2
20
Design of the Output Module CPX-FVDA-P2
24
Design in a CPX Terminal
24
Design in a Valve Terminal VTSA-F-CB
25
Components
26
Supported Product Versions
29
Required Bus Topology (Control Chain)
32
Profisafe
32
Profisafe Safety Profile
32
Process Image
33
Bit Pattern of the Output and Input Data (F-User Data)
34
Mode of Operation of the Output Module
37
Possible Applications
38
Application Examples
41
Actuator Requirements (CH0
54
Electrical Requirements
54
Safety-Related Requirements
56
3 Installation
56
General Information about Installation
56
Module-Related Rules for Configuration
57
Connecting the Cables and Plugs to the Manifold Block
57
Electrical Connection and Display Elements
59
Pin Allocation with M12 Manifold Block
60
Pin Allocation with TS Manifold Block
61
Pin Allocation with Pneumatic Interface VABA-S6-1-X
62
Setting the Profisafe Address
62
Disassembling and Assembling the Electronics Module
64
Disassembling the Electronics Module
64
Assembling the Electronics Module
64
4 Commissioning
66
General Information
66
Device Master File (GSD/GSDML)
66
Preparing for Commissioning
67
Commissioning Steps
67
Setting the Profisafe Parameters
68
Setting the CPX Module Parameters
69
CPX Module Parameters for CPX-FVDA-P2 in Detail
71
Parameterisation and Signal Display with the Operator Unit CPX-MMI-1
74
Configuration with Siemens STEP 7 (Example)
76
Addressing Example
79
5 Operation
80
LED Status Indication
80
Behaviour During the Switch-On Phase (Start-Up Phase)
81
Normal Operating Status
81
6 Diagnostics and Error Handling
81
Overview of Diagnostics Options
81
Possible Error Messages of the Output Module CPX-FVDA-P2
82
Diagnostics Via Leds
85
Error Handling and Parameterisation
88
Behaviour in Case of Error
90
Diagnostics Via the CPX Bus Node
91
Diagnostics with the Operator Unit CPX-MMI
91
7 Service, Repair, Disposal
91
Service
91
Repair
92
Disposal
92
8 Technical Appendix
92
Technical Data of the Output Module CPX-FVDA-P2
92
Advertisement
Festo CPX-FVDA-P2 Brief Description (60 pages)
Output module
Brand:
Festo
| Category:
Control Unit
| Size: 0.47 MB
Table of Contents
Deutsch
3
Table of Contents
3
1 Sicherheitshinweise
4
Bestimmungsgemäße Verwendung
5
Regeln zum Produktaufbau
6
Vorhersehbare Fehlanwendung
8
Erreichbares Sicherheitsniveau
9
Ausfälle Aufgrund Gemeinsamer Ursache (Common Cause Failure - CCF)
9
Voraussetzungen für den Produkteinsatz
10
Technische Voraussetzungen
10
Qualifikation des Fachpersonals
11
Transport- und Lagerbedingungen
11
Service
11
Einsatzbereich und Zulassungen
12
2 Produktidentifikation
13
3 Anschluss- und Anzeigeelemente
15
Aufbau des Ausgangsmoduls
15
4 Installation
16
Profisafe-Adresse Einstellen
17
Demontage des Elektronikmoduls
18
Montage des Elektronikmoduls
19
Pin-Belegung
20
5 Inbetriebnahme
22
Startverhalten des Ausgangsmoduls
22
6 Wartung, Reparatur, Entsorgung
24
7 Technische Daten
25
English
31
1 Safety Instructions
32
Intended Use
33
Rules for Product Configuration
34
Foreseeable Misuse
36
Attainable Safety Level
37
Common Cause Failures (CCF)
37
Requirements for Product Use
38
Technical Prerequisites
38
Training of Qualified Personnel
39
Transport and Storage Conditions
39
Service
39
Range of Application and Certifications
40
2 Product Identification
41
3 Connection and Display Components
43
Design of the Output Module
43
4 Installation
44
Setting the Profisafe Address
45
Dismounting the Electronics Module
46
Mounting the Electronics Module
47
Pin Allocation
48
5 Commissioning
50
Start Behaviour of the Output Module
50
6 Service, Repair, Disposal
52
7 Technical Data
53
Festo CPX-FVDA-P2 Operating Instruction (7 pages)
Output module
Brand:
Festo
| Category:
Control Unit
| Size: 1.19 MB
Festo CPX-FVDA-P2 Manual (6 pages)
Output Module
Brand:
Festo
| Category:
Control Unit
| Size: 1.25 MB
Advertisement
Related Products
Festo CPX-FB32
Festo CPX-FB23
Festo CPX-FB23-24
Festo CPX-FB39
Festo CPX-FB40
Festo CPX-FB14
Festo CPX-FB6
Festo CPX-F8DE-P
Festo CPX-FVDA-P
Festo CPX-SF35
Festo Categories
Industrial Equipment
Control Unit
Controller
Touch terminals
DC Drives
More Festo Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL