Installation

6.3

Assembly with MS-series service unit components

WARNING!
Failure of the safety function.
Incorrect installation in the service unit combination can result in failure of the exhaust safety func-
tion.
Only devices that do not impair the exhaust process, even after a possible malfunction of the
device, may be placed downstream from the MS6-SV-....
Fig. 15 Assembly
1. Slide the cover cap MS6-END 1 upwards and remove it.
2. Insert a seal 2 between the individual devices (module connector MS6-MV in scope of delivery).
3. Place module connector 2 in the slots of the individual devices.
4. Fasten the module connector with two screws (product scope of delivery). Tightening torque: max-
imum1.2 Nm.
7
Installation
7.1

Pneumatic Installation

Port 1 and 2
If using screw connectors:
Note the screw-in depth of the connector thread: 10 mm.
Make sure that the compressed air lines are connected correctly.
Screw the connectors into the pneumatic connections using a suitable sealing material.
Festo — MS6-SV-...-E-10V24 — 2019-10d