DGS-3630 Series Layer 3 Stackable Managed Switch Web UI Reference Guide
Trap Name
Safeguard
Trap Name
dSafeguardChgToExhausted
dSafeguardChgToNormal
SIM
Trap Name
swSingleIPMSColdStart
swSingleIPMSWarmStart
swSingleIPMSLinkDown
swSingleIPMSLinkUp
swSingleIPMSAuthFail
Description
is configured for sending SNMP traps.
Binding objects:
(1) alarmIndex
(2) alarmVariable
(3) alarmSampleType
(4) alarmValue
(5) alarmFallingThreshold
Description
This trap indicates System change operation mode from
normal to exhaust.
Binding objects:
(1) dSafeguardEngineCurrentMode
This trap indicates system change operation mode from
exhausted to normal.
Binding objects:
(1) dSafeguardEngineCurrentMode
Description
The commander Switch will send this notification when its
member generates a cold start notification.
Binding objects:
(1) swSingleIPMSID
(2) swSingleIPMSMacAddr
The commander Switch will send this notification when its
member generates a warm start notification.
Binding objects:
(1) swSingleIPMSID
(2) swSingleIPMSMacAddr
The commander Switch will send this notification when its
member generates a link down notification.
Binding objects:
(1) swSingleIPMSID
(2) swSingleIPMSMacAddr
(3) ifIndex
The commander Switch will send this notification when its
member generates a link up notification.
Binding objects:
(1) swSingleIPMSID
(2) swSingleIPMSMacAddr
(3) ifIndex
The commander Switch will send this notification when its
member generates an authentication failure notification.
Binding objects:
675
OID
OID
1.3.6.1.4.1.171
.14.19.1.1.0.1
1.3.6.1.4.1.171
.14.19.1.1.0.2
OID
1.3.6.1.4.1.171
.12.8.6.0.11
1.3.6.1.4.1.171
.12.8.6.0.12
1.3.6.1.4.1.171
.12.8.6.0.13
1.3.6.1.4.1.171
.12.8.6.0.14
1.3.6.1.4.1.171
.12.8.6.0.15

Advertisement

Table of Contents
loading

Table of Contents