DDM Temperature Threshold Settings

This window is used to display and configure the DDM Temperature Threshold Settings for specific ports on the
Switch.
To view the following window, click OAM > DDM > DDM Temperature Threshold Settings, as shown below:
The fields that can be configured are described below:
Parameter
Unit
Port
Action
Type
Value
Click the Apply button to accept the changes made.

DDM Voltage Threshold Settings

This window is used to display and configure the DDM Voltage Threshold Settings for specific ports on the Switch.
To view the following window, click OAM > DDM > DDM Voltage Threshold Settings, as shown below:
Figure 10-28 DDM Temperature Threshold Settings Window
Description
Select the Switch unit that will be used for this configuration here.
Select the port used for the configuration here.
Select the action that will be taken here. Options to choose from are Add and
Delete.
Select the type of temperature threshold. Options to choose from are Low Alarm,
Low Warning, High Alarm, and High Warning.
Enter the threshold value. This value must be between -128 and 127.996 °C.
Figure 10-29 DDM Voltage Threshold Settings Window