This is the final result:
Cue
Fixture 1
number
Dim
100
1
0
2
100
3
0
4
0
5
100
6
This is the principle behind Tracking Shield:
The system looks for dimmer values that changes from 0 to above 0 for each single fixture. If there's a change in the
dimmer (from 0 to a value above), then it stores the tracked values before creating the new values in the previous
cues, thus preventing the cue output from changing because of the tracking.
The dimmer value in cue 5 is a tracked value even though we store both 4 and 5 as Cue Only because of a function
AutoUnblock
called
. It's the same mechanism that made the dimmer in cue 6 a tracked value after we stored cue
3. AutoUnblock will automatically remove unnecessary stored values after each store operation.