MA lighting dot2 User Manual page 121

Control console
Hide thumbs Also See for dot2:
Table of Contents

Advertisement

d o t 2 U s e r Ma n u a l
Auto Unblock
Updating the cue will do an
. This means that after an update all stored, but unchanged values are
Protect
removed. Please use the
function (read below) if you want to "block" a cue.
Naming a cue
Right after you store a cue there's the Label pop-up. If you press this, then you are taken to the
Enter Name for
window.
If you need to label a cue after it's created, then you can use the
Label
key. E.g. you want to label cue number 2
in the main executor:
Label Cue 2 Please
.
You can also open a
Cues view
and press in the cue name you want to change. If you keep pressing it for around 2
seconds, then you also get the Enter Name for window.
Change the cue timing
There are many different timings in a cue. They can be seen in the
Cue
view.
The usual (In)Fade and Out Fade values set the times used respectively by the attributes going up in value and the
attributes going down in value. The factory default is that the Out Fade is set to the Fade (or InFade) time. So no
matter what you set the fade time to, then the OutFade will be the same. But you have the possibility to separate
them.
You can also set a delay for the OutFade. This is a time that the console will wait before beginning the OutFade.
All available Preset Types have their own timings for fade and delay. Setting this will overwrite the set cue timing for
the values changing in that Preset Type.
Default timing
You can press the
Time
key to open the
Time Defaults
window. Here you can set the times that will be used as a
default when you create new cues.
Set a time when storing
You can overwrite the default timing when you store a cue. E.g. you want to store cue 3 with a fade time of 5
seconds:
Store Cue 3 Time
(= Fade command)
5 Please
.
The
Time
key have a special function when you use it in a command. In the above example you can keep pressing
the
Time
key to change between the different available timings in the cue - although not the preset type timings.
Change timing in Cues view
When you have a Cues view visible then you can press and hold on a value in the view to change the time value.
You can also use the scroll encoder to select the time field you want to change and then tap the encoder. This will
give you the
Calculator
view. Use this to set the new value.
You can also press the
Edit
key and then the field in the Cues view that you want to change, this also gives you the