If swop protect is on, the dimmer values of this executor are not set to zero when an other swop executor is on.
Restart Mode
To select the restart mode, tap at the three dots
There are two different restart modes available:
First
(default): The executor starts with the first cue.
Current:
The executor starts with the current cue.
Cue Zero
To activate cue zero for the executor, tap at the prohibition sign.
If cue zero is on, the dot2 creates a not visible cue zero on this executor.
The cue zero stores the default values of any attributes which are used in any cue on this executor.
If cue zero is on, any attributes which are used in any cue on this executor will have their default values additional to
the values of the current cue.
For more information about tracking, refer to
Example Cue Zero On:
Let´s assume, you have stored fixture 1 thru 3 in blue at executor 1.
In cue 1 of executor 2 is fixture 1 stored in red.
In cue 2 of executor 2 is fixture 2 stored in green.
In cue 3 of executor 2 is fixture 3 stored in green.
Cue zero is on for executor 2.
Start executor 1 gives you three fixtures in blue.
Figure 3: Fixture 1 thru 3 blue
Start cue 1 of executor 2 gives you fixture 1 in red.
Fixture 2 and 3 have their default values because they are used on executor 2 in cue 2 and cue 3.
Figure 4: Fixture 1 red - cue zero on
Example Cue Zero Off:
Same initial situation as in example cue zero on.
© 2016 MA Lighting Technology Gm bH | Dachdeck erstr. 16 | D-97297 W aldbüttelbrunn | Germ any